VDD_2V0_L_and_R

Measurement Report

Test Information

Instrument: Keysight MSOX4154A Oscilloscope

Timestamp: 2025-10-01 16:24:06.135768

Statistics Mode: ON

Input Directory: captures\Board_00003\VDD_2V0_L_and_R

Raw Response: Pk-Pk(1),+110E-03,+12E-03,+121E-03,+113.610421836229E-03,+3.05666292759770E-03,2015,RMS - Full Screen(1),+2.00E+00,+1.80E+00,+2.00E+00,+1.99990084283590E+00,+4.45324969219393E-03,2017

Oscilloscope Configuration

Acquisition Settings

Acquisition Mode: NORM

Time Scale: +200.0E-09

CH1 Settings

Voltage Scale: +50E-03

Bandwidth Limit: 0

Coupling: DC

Offset: +1.93250E+00

Measurement Results

Measurement Current Minimum Maximum Mean Std Dev Count
Pk-Pk(1) 0.110000 0.012000 0.121000 0.113610 0.003057 2015
RMS - Full Screen(1) 2.000000 1.800000 2.000000 1.999901 0.004453 2017

Oscilloscope Screenshot

Oscilloscope Screenshot

Interactive Waveform Plots

CH1 Waveform

M1 Math Waveform